Use este identificador para citar ou linkar para este item: http://www.alice.cnptia.embrapa.br/alice/handle/doc/1065497
Título: Determination of elemental impurities in acyclovir ointment and raw materials using microwave acid digestion (MW-AD) and ICP-MS.
Autoria: GONZALEZ, M. H.
SILVA, C. S. da
AMARAL, C. D. B. do
BIANCHI, S. R.
OLIVEIRA, L. H. B. de
COELHO, J. S.
OLIVEIRA, A.
NOGUEIRA, A. R. de A.
Afiliação: Mario Henrique Gonzalez, UNESP; Caroline Santos da Silva, UFSCar; Clarice Dias Britto do Amaral, UFSCar; SILMARA ROSSANA BIANCHI, CNPS; Luciano Henrique Barca de Oliveira, UNESP; Jessica Silva Coelho, UNESP; Andrea Oliveira, UFPR; ANA RITA DE ARAUJO NOGUEIRA, CPPSE.
Ano de publicação: 2017
Referência: Journal of the Brazilian Chemical Society, v. 28, n. 1, p. 98-105, 2017.
Conteúdo: Inorganic elements present in pharmaceutical products were determined by inductively coupled plasma-mass spectrometer (ICP-MS), employing microwave acid digestion as a sample preparation method. The most abundant isotopes, 75As+ , 65Cu+ , 52Cr+ , 58Ni+ , 208Pb+ , and 51V+ , were determined in acyclovir ointment and its constituents. Elemental impurities in the pharmaceutical samples were determined using an inductively coupled plasma-universal cell technology-mass spectrometer (ICP-UCT-MS) operated in kinetic energy discrimination (KED) and standard mode. The accuracy of the method was assessed by means of addition and recovery experiments. Except for Cr, spiked recoveries of the elements added to the samples before microwave acid digestion (MW-AD) step were between 95.1 and 126%, and after MW-AD step ranged from 85.6 to 132%. Limits of detection (LOD) obtained by proposed method is in agreement to those required by the U.S. Pharmacopeia Convention (USP), showing that the ICP-MS technique is well suited for quantification of these elements. The LOD?s (ng L-1) for 51V+ , 52Cr+ , 58Ni+ , 65Cu+ , 75As+ and 208Pb+ in 1% v v-1 HNO3 medium were: 2.2, 81.3, 91.9, 6.9, 0.2 and 3.1, respectively. The concentration of the analytes in these samples presented a wide range, varying from 2.3 ± 0.8 µg kg-1 for As to 3446 ± 47 µg kg-1 for Cr.
Palavras-chave: Pharmaceutical product
Elemental impurity
Acyclovir
Digital Object Identifier: http://dx.doi.org/10.5935/0103-5053.20160151
Tipo do material: Artigo de periódico
Acesso: openAccess
Aparece nas coleções:Artigo em periódico indexado (CPPSE)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
01035053jbchs28010098.pdf361,71 kBAdobe PDFThumbnail
Visualizar/Abrir

FacebookTwitterDeliciousLinkedInGoogle BookmarksMySpace