Título: | Avaliação em escala laboratorial da utilização do processo eletrolítico no tratamento de águas. |
Autor: | OTENIO, M. H. PANCHONI, L. C. CRUZ, G. C. A. RAVANHANI, C. BIDÓIA, E. D. |
Afiliación: | Marcelo Henrique Otênio, Embrapa Gado de Leite; Luciana Cadioli Panchoni, SAAE-PR; Gabriela Correia Araújo da Cruz, SAAE-PR; Clézio Ravanhani, SAAE-PR; Ederio Dino Bidóia, Unesp. |
Año: | 2008 |
Referencia: | Química Nova, v. 31, n. 3, p. 508-813, 2008. |
Descripción: | Water treatment uses chlorine for disinfection causing formation of trihalomethanes. In this work, an electrolytic water pre-treatment was studied and applied to the water from a fountainhead. The action against microorganisms was evaluated using cast-iron and aluminum electrodes. Assays were made in laboratory using the electrolytic treatment. After 5 min of electrolysis the heterotrophic bacteria count was below 500 cfu/mL and complete elimination of total and fecal coliforms was observed. Using electrolytic treatment as a pretreatment of conventional tap water treatment is proposed. |
Thesagro: | Qualidade da Água Desinfecção |
Palabras clave: | Tratamento eletrolítico |
Tipo de Material: | Artigo de periódico |
Acceso: | openAccess |
Aparece en las colecciones: | Artigo em periódico indexado (CNPGL) |
Ficheros en este ítem:
Fichero | Tamaño | Formato | |
---|---|---|---|
Avaliacao-em-escala-laboratorial.pdf | 311,07 kB | Adobe PDF | Visualizar/Abrir |