Use este identificador para citar ou linkar para este item: http://www.alice.cnptia.embrapa.br/alice/handle/doc/1132812
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorMACHADO, R. C.eng
dc.contributor.authorSILVA, A. B. S. daeng
dc.contributor.authorANDRADE, D. F. deeng
dc.contributor.authorPINHEIRO, F. C.eng
dc.contributor.authorWILLIAMS, C. B.eng
dc.contributor.authorDONATI, G. L.eng
dc.contributor.authorNOGUEIRA, A. R. de A.eng
dc.contributor.authorPEREIRA FILHO, E. R.eng
dc.date.accessioned2021-07-06T15:01:10Z-
dc.date.available2021-07-06T15:01:10Z-
dc.date.created2021-07-06
dc.date.issued2021
dc.identifier.citationJournal of the Brazilian Chemical Society, v.32, n.4, 2021.
dc.identifier.issn0103-5053
dc.identifier.urihttp://www.alice.cnptia.embrapa.br/alice/handle/doc/1132812-
dc.descriptionMulti-flow calibration (MFC) is based on monitoring the analytical signal from a single calibration standard solution at several different nebulization gas flow rates (Q), which normalizes plasma conditions and minimizes matrix effects. In the present study, MFC was evaluated, for the first time, applied to inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS) to analyze different and complexmatrix samples. Al, As, Cd, Cr, Cu, Mn, Pb, and Zn were determined by ICP OES, while As, Cd, Co, Cu, Hg, Mo, Mn, Ni, Se, Sb, Pb, and V were determined by ICP-MS. MFC results were compared with those obtained using external standard calibration (EC) for both techniques and in all cases, MFC showed equal or superior accuracy (recoveries between 80-120%) compared to EC, and lower relative standard deviation (RSDs < 10%). Several tests were also performed using only two nebulization gas flows to build linear models for calibration (called two-flow calibration, TFC) and the accurate results (recoveries ranged from 80 to 110% for ICP OES and from 81 to 102% for ICP-MS) suggests that this strategy can be also applied, resulting in a method with high sample throughput.
dc.language.isoeng
dc.rightsopenAccesseng
dc.subjectNebulization gas
dc.subjectCalibration strategy
dc.subjectMatrix effects
dc.subjectICP OES
dc.subjectICP-MS
dc.titleAlternative approaches applied to inductively coupled plasma techniques: multi-flow and two-flow calibration.
dc.typeArtigo de periódico
dc.format.extent2p.842-851.
riaa.ainfo.id1132812
riaa.ainfo.lastupdate2021-07-06
dc.identifier.doihttps://dx.doi.org/10.21577/0103-5053.20200235
dc.contributor.institutionRAQUEL CARDOSO MACHADO, UFSCAReng
dc.contributor.institutionANA BEATRIZ SANTOS DA SILVA, UFSCAReng
dc.contributor.institutionDANIEL FERNANDES DE ANDRADE, UFSCAReng
dc.contributor.institutionFERNANDA COSTA PINHEIRO, UFSCAReng
dc.contributor.institutionCHARLES B. WILLIAMS, Davidson Collegeeng
dc.contributor.institutionGEORGE LUIS DONATI, Wake Forest Universityeng
dc.contributor.institutionANA RITA DE ARAUJO NOGUEIRA, CPPSEeng
dc.contributor.institutionEDENIR RODRIGUES PEREIRA FILHO, UFSCAR.eng
Aparece nas coleções:Artigo em periódico indexado (CPPSE)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Alternative-Approaches-Applied.pdf496.32 kBAdobe PDFThumbnail
Visualizar/Abrir

FacebookTwitterDeliciousLinkedInGoogle BookmarksMySpace