Por favor, use este identificador para citar o enlazar este ítem: http://www.alice.cnptia.embrapa.br/alice/handle/doc/1188638
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorCASTELO, R. M.
dc.contributor.authorOLIVEITA, M. de A.
dc.contributor.authorMENEZES, D. O.
dc.contributor.authorSANTANA, R. S. de
dc.contributor.authorMELO, A. M. A.
dc.contributor.authorFURTADO, R. F.
dc.contributor.authorMACHADO, T. F.
dc.contributor.authorALVES, C. R.
dc.date.accessioned2026-07-27T14:48:56Z-
dc.date.available2026-07-27T14:48:56Z-
dc.date.created2026-07-27
dc.date.issued2026
dc.identifier.citationEuropean Food Research and Technology, v. 252, n. 3, 154, Mar. 2026.
dc.identifier.issn1438-2385
dc.identifier.urihttp://www.alice.cnptia.embrapa.br/alice/handle/doc/1188638-
dc.descriptionThe sandwich amperometric immunosensor based on pequi- derived carbon dots (CDs) for labeling second antibody represents a promising approach for a rapid and quantitative detection of Salmonella sp. in liquid (water used for washing chicken- CWW) and solid (cheese- CC1) samples. The original microbiota of each sample was preserved, and each one was intentionally contaminated with Salmonella enterica serovar Typhimurium. The immunosensor was tested in the presence of Escherichia coli and Staphylococcus aureus, it exhibited specificity and effectively detected Salmonella with a low limit of detection (LOD) which was 0.8 CFU/mL and 0.1 CFU/mL for CWW and CC1, respectively. The electrochemical measurement time was two minutes without pre-enrichment step of the pathogen and the total assay time was about two hours. This study demonstrates the potential of this immunosensor for a rapid and sensitive Salmonella detection in real samples.
dc.language.isopor
dc.rightsopenAccess
dc.subjectPequi-nut
dc.subjectCarbon dots
dc.subjectChicken washing water
dc.subjectImunosensores
dc.subjectAmêndoa de pequi
dc.subjectPontos de carbono
dc.subjectÁgua de lavagem de frango
dc.titleDetection of Salmonella typhimurium in food matrices by an amperometric immunosensor with Pequi carbon dot- labeled antibody.
dc.typeArtigo de periódico
dc.subject.thesagroSalmonella
dc.subject.thesagroQueijo
dc.subject.nalthesaurusImmunosensors
dc.subject.nalthesaurusCheeses
dc.description.notesTítulo: dot- labeled [i.e. dot-labeled].
riaa.ainfo.id1188638
riaa.ainfo.lastupdate2026-07-27
dc.identifier.doihttps://doi.org/10.1007/s00217-026-05074-z
dc.contributor.institutionRACHEL MENEZES CASTELO, UNIVERSIDADE ESTADUAL DO CEARÁ; MARÍLIA DE ALBUQUERQUE OLIVEIRA, UNIVERSIDADE ESTADUAL DO CEARÁ; DENILSON OLIVEIRA MENEZES, UNIVERSIDADE ESTADUAL DO CEARÁ; RUAN SOUSA DE SANTANA, UNIVERSIDADE ESTADUAL DO CEARÁ; AIRIS MARIA ARAÚJO MELO, INSTITUTO FEDERAL DE EDUCAÇÃO, CIÊNCIA E TECNOLOGIA DO PIAUÍ; ROSELAYNE FERRO FURTADO, CNPAT; TEREZINHA FEITOSA MACHADO, CNPAT; CARLUCIO ROBERTO ALVES, UNIVERSIDADE ESTADUAL DO CEARÁ.
Aparece en las colecciones:Artigo em periódico indexado (CNPAT)


FacebookTwitterDeliciousLinkedInGoogle BookmarksMySpace