Use este identificador para citar ou linkar para este item: http://www.alice.cnptia.embrapa.br/alice/handle/doc/17096
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorMARIN, F. R.pt_BR
dc.contributor.authorANGELOCCI, L. R.pt_BR
dc.contributor.authorRIGHI, E. Z.pt_BR
dc.date.accessioned2015-03-13T02:34:10Z-
dc.date.available2015-03-13T02:34:10Z-
dc.date.created2004-05-14pt_BR
dc.date.issued2004pt_BR
dc.identifier.citationIn: REUNIÓN ARGENTINA Y LATINOAMERICANA DE AGROMETEOROLOGIA, 10., 4., 2004, Mar del Plata, Argentina. [Anais]: Agrometeorologia y Seguridad Alimentaria en América Latina. Mar del Plata, Argentina: AADA, 2004.pt_BR
dc.identifier.urihttp://www.alice.cnptia.embrapa.br/alice/handle/doc/17096pt_BR
dc.descriptionCermak et al. (1973) developed the first version of the heat balance method (HBM), which involves continuous application of heat in a stem segment and quantifying losses by axial and radial wood conduction. The heat flow carried out by the sap is determined from the difference between input power and axial and radial heat losses from the heated stem segment. Currently, this method follows Sakuratani (1981) and Baker & Van Bavel (1987), who modified the first HBM version by applying a constant power on the gauge, so reducing the electronic requirements for the measurements. The HBM is an absolute method that requires simple equipment and some basic procedures in order to minimize errors (Baker & Nieber, 1989; Steinberg et al., 1990; Valancogne & Nasr, 1993; Weibel & de Vos, 1994). However, it is difficult to evaluate sap flow measurements in field conditions since reference methods, such as lysimeters, soil water balance and other techniques are normally difficult to apply, especially for big plants. This paper focuses on this problem and considers some procedures to evaluate data supplied by HBM when reference methods are not available.pt_BR
dc.format1 CD-ROM.pt_BR
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectHeat Balance Methodpt_BR
dc.titlePreliminary evaluation of sap flow data by stem heat balance method.pt_BR
dc.typeArtigo em anais e proceedingspt_BR
dc.date.updated2015-03-13T02:34:10Zpt_BR
riaa.ainfo.id17096pt_BR
riaa.ainfo.lastupdate2015-03-12pt_BR
dc.contributor.institutionFÁBIO RICARDO MARIN, CNPM; LUIZ ROBERTO ANGELOCCI; EVANDRO ZANINI RIGHI.pt_BR
Aparece nas coleções:Artigo em anais de congresso (CNPM)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
1238.pdf109,89 kBAdobe PDFThumbnail
Visualizar/Abrir