Use este identificador para citar ou linkar para este item:
http://www.alice.cnptia.embrapa.br/alice/handle/doc/959237
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | SUAREZ, W. T. | |
dc.contributor.author | PESSOA NETO, O. D. | |
dc.contributor.author | SANTOS, V. B. dos | |
dc.contributor.author | NOGUEIRA, A. R. de A. | |
dc.contributor.author | FARIA, R. C. | |
dc.contributor.author | FATIBELLO-FILHO, O. | |
dc.contributor.author | CHAMARRO, J. A. | |
dc.date.accessioned | 2023-05-15T12:47:12Z | - |
dc.date.available | 2023-05-15T12:47:12Z | - |
dc.date.created | 2013-06-04 | |
dc.date.issued | 2013 | |
dc.identifier.citation | Journal Brazilian Chemical Society, v. 24, n. 5, p. 847-855, may 2013. | |
dc.identifier.uri | http://www.alice.cnptia.embrapa.br/alice/handle/doc/959237 | - |
dc.description | In this work, an analytical microsystem based on LTCC (low-temperature co-fired ceramic) technology with monolithic incorporation of an optical flow cell for determination of dipyrone in pharmaceuticals is described. The detection system is based on the formation of a blue chromophore between dipyrone and Fe(III) photometrically monitored at 630 nm using a lab-made LED mini-photometer constructed with a light emitting diode as a radiation source and a Si photodiode as a detector. The lab-made mini-photometer elaborated presented a good performance in regard to high signal/noise ratio, low drift and good sensitivity. The analytical curve was linear in the dipyrone concentration range from 1.0 × 10-4 to 3.5 × 10-3 mol L-1, limit of detection of 4.5 × 10-5 mol L-1 and total time of analyses of 20 s yielding an analytical frequency of 195 h-1 with a low waste generation per analysis (480 µL). | |
dc.language.iso | eng | |
dc.rights | openAccess | |
dc.subject | Low temperature | |
dc.subject | Co-fired ceramic | |
dc.subject | Analytical microsystems | |
dc.subject | Dipyrone | |
dc.subject | Flow injection | |
dc.subject | LED photometer | |
dc.title | A compact miniaturized flow system based on low-temperature co-fired ceramic technology coupled to led mini-photometer for determination of dipyrone in pharmaceutical formulations. | |
dc.type | Artigo de periódico | |
riaa.ainfo.id | 959237 | |
riaa.ainfo.lastupdate | 2023-05-15 | |
dc.identifier.doi | https://doi.org/10.5935/0103-5053.20130112 | |
dc.contributor.institution | WILLIAN T. SUAREZ, Universidade Federal de Viçosa; OSMUNDO D. PESSOA-NETO, Universidade Federal de São Carlos; VAGNER B. DOS SANTOS, Universidade Federal de São Carlos; ANA RITA DE ARAUJO NOGUEIRA, CPPSE; RONALDO C. FARIA, Universidade Federal de São Carlos; ORLANDO FATIBELLO-FILHO, Universidade Federal de São Carlos; JULIÁN A. CHAMARRO, Universitat Autònoma de Barcelona. | |
Aparece nas coleções: | Artigo em periódico indexado (CPPSE)![]() ![]() |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
PROCI-2013.00023.pdf | 1.17 MB | Adobe PDF | ![]() Visualizar/Abrir |