dc.descriptionThis technical note describes a small ruminant respiration chamber system designed to accurately quantify the production of carbon dioxide (CO2) and methane (CH4). The system consists of 3 open-circuit respiration chambers, flow meters, gas analyzers, and an accessible environmental control system. To validate its performance, gas recovery tests were conducted by injecting CO2 and CH4 at 4 constant flow rates: 0.4, 0.8, 1.2, and 1.6 standard liters per minute (SLPM) for CO2, and 0.16, 0.20, 0.24, and 0.28 SLPM for CH4. Each injection level was tested across the 3 chambers. The average percentage recoveries for CO2 and CH4 were 97.8% ± 1.46% for chamber 1, 101.1% ± 1.49% for chamber 2, and 104.1% ± 1.98% for chamber 3 and 98.7% ± 0.97% for chamber 1, 99.4% ± 2.06% for chamber 2, and 101.6% ± 2.90% for chamber 3, respectively, demonstrating the system’s accuracy in quantifying livestock GHG emissions from small ruminants, such as young cattle, goats, and sheep. Therefore, this system represents a viable methodology for nutritional and environmental studies with small ruminants. Future studies conducted in this facility can contribute to a better understanding of the dynamic and flow of GHG emissions in small ruminants and target measures to increase the sustainability of small ruminant production systems.
dc.language.isoeng
dc.rightsopenAccess
dc.subjectCâmara respiratória
dc.titleA respirometry system designed for small ruminants.
dc.typeArtigo de periódico
dc.subject.thesagroBovino
dc.subject.thesagroRuminante
riaa.ainfo.id1178364
riaa.ainfo.lastupdate2025-08-28
dc.identifier.doihttps://doi.org/10.3168/jdsc.2025-0755
dc.contributor.institutionUNIVERSIDADE FEDERAL RURAL DE PERNAMBUCO
dc.contributor.institutionUNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIROeng
dc.contributor.institutionUNIVERSIDADE ESTADUAL JULIO DE MESQUITA FILHOeng
dc.contributor.institutionRAFAEL GONCALVES TONUCCI, CNPGLeng
dc.contributor.institutionTHIERRY RIBEIRO TOMICH, CNPGLeng
dc.contributor.institutionFERNANDA SAMARINI MACHADO, CNPGLeng
dc.contributor.institutionMARIANA MAGALHAES CAMPOS, CNPGL.eng
Aparece nas coleções:Nota Técnica/Nota científica (CNPGL)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
A-respirometry-system-designed-for-small-ruminants.pdf1.09 MBAdobe PDFThumbnail
Visualizar/Abrir

FacebookTwitterDeliciousLinkedInGoogle BookmarksMySpace