Por favor, use este identificador para citar o enlazar este ítem: http://www.alice.cnptia.embrapa.br/alice/handle/doc/1179317
Título: Powerflow doppler ultrasonography in the evaluation of mares with and without endometritis.
Autor: FERREIRA, C. S. C.
PINNA, A. E.
SANTOS, I. P. F. dos
DIAS, M. C. R.
SANTOS, N. S. L. dos
BRAGUEROLI, S. da S.
QUINTINO, P. M.
ALMEIDA, G. B.
PENNA, B. de A.
ROCHA, E. M. da S. da
SOUZA, G. N. de
BARBOSA, C. G.
JESUS, V. L. T. de
JACOB, J. C. F.
Afiliación: CAMILA SILVA COSTA FERREIRA, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO; ALINE EMERIM PINNA, UNIVERSIDADE FEDERAL FLUMINENSE; ISADORA PIRES FERREIRA DOS SANTOS, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO; MARIA CLARA RANGEL DIAS, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO; NATÁLIA SALES LEAL DOS SANTOS, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO; SAMANTA DA SILVA BRAGUEROLI, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO; PETRUSKA MONTEZUMA QUINTINO, UNIVERSIDADE FEDEREAL RURAL DO RIO DE JANEIRO; GIOVANNA BRITO ALMEIDA, UNIVERSIDADE FEDERAL FLUMINENSE; BRUNO DE ARAÚJO PENNA, UNIVERSIDADE FEDERAL FLUMINENSE; ELISABETH MARTINS DA SILVA DA ROCHA, UNIVERSIDADE FEDERAL FLUMINENSE; GUILHERME NUNES DE SOUZA, CNPGL; CELSO GUIMARÃES BARBOSA, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO; VERA LUCIA TEIXEIRA DE JESUS, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO; JULIO CÉSAR FERRAZ JACOB, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO.
Año: 2025
Referencia: Veterinary Sciences, v. 12, 941, 2025.
Descripción: There are no reports on the application of Powerflow mode Doppler ultrasound (US) in the diagnosis of endometritis when evaluating mares with or without endometritis. Therefore, our objective was to evaluate the blood flow of the uterine segments by Powerflow mode Doppler US, relating it to the days of the estrous cycle of mares with endometritis. The mares were separated into three groups: CG—control group with mares without endometritis; GES—group of mares with subclinical endometritis; and GEC—group of mares with clinical endometritis. With ovulation induction, the mares were monitored by transrectal B-mode US and Powerflow mode Doppler US of the uterine segments. The examinations were performed daily until the next ovulation. The subjective evaluation, performed by Powerflow mode Doppler ultrasound, proved to be efficient in detecting mares with clinical endometritis examined on days 1, 9, and 10 of the estrous cycle (p < 0.0001). It was found that subjective and objective evaluation of pixel quantity and intensity showed a significant, positive, and moderate correlation with ρ = 0.51 and ρ = 0.51, respectively (p < 0.0001). Thus, it is concluded that Powerflow Doppler ultrasound can be used to detect mares with clinical endometritis.
Thesagro: Égua
Endometrite
Doença Animal
Reprodução Animal
Palabras clave: Patologia uterina
DOI: https://doi.org/10.3390/vetsci12100941
Tipo de Material: Artigo de periódico
Acceso: openAccess
Aparece en las colecciones:Artigo em periódico indexado (CNPGL)

Ficheros en este ítem:
Fichero TamañoFormato 
Powerflow-doppler-ultrasonography-in-the-evaluation-of-mares.pdf4.36 MBAdobe PDFVisualizar/Abrir

FacebookTwitterDeliciousLinkedInGoogle BookmarksMySpace