Please use this identifier to cite or link to this item: http://www.alice.cnptia.embrapa.br/alice/handle/doc/1187968
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMATTOS, S. S. F.
dc.contributor.authorSILVA, C. G. da
dc.contributor.authorLIMA, L. B. de
dc.contributor.authorMAIA, L. R.
dc.contributor.authorDILELIS, F.
dc.contributor.authorSILVA, T. E. da
dc.contributor.authorMARTINHO, P. de F.
dc.contributor.authorRUFINO, L. M. de A.
dc.contributor.authorRODRIGUES, J. P. P.
dc.date.accessioned2026-07-28T17:48:47Z-
dc.date.available2026-07-28T17:48:47Z-
dc.date.created2026-07-02
dc.date.issued2026
dc.identifier.citationRevista Brasileira de Zootecnia, v. 55, e20250130, 2026.
dc.identifier.urihttp://www.alice.cnptia.embrapa.br/alice/handle/doc/1187968-
dc.descriptionThis study aimed to evaluate the potential of using images taken with a smartphone or scanner as alternatives to conventional spectrophotometry for phosphorus (P) analysis of feedstuff. Twenty-four samples of feed ingredients and commercial concentrates were evaluated. After acid digestion and dilution, the solutions were analyzed using the P-molybdate colorimetric reaction. Standards ranged from 0 to 1.4 mg L−1 at intervals of 0.2 mg L−1 of P in the reading solution. Standards and reading solutions were analyzed in ELISA microplates. The absorbance values of each cuvette were obtained using a spectrophotometer, and smartphone and scanner images were obtained sequentially. The images were segmented, and a circle was sampled in each cuvette to obtain the mean values of the red, green, and blue (RGB) channels. The P concentration was determined using linear regression of absorbance or the mean values obtained in the RGB channels as a function of P concentration. The repeatability (REP), limits of detection (LOD), and limits of quantification (LOQ) were calculated. Except for the scanner’s blue channel (P<0.10), image-based colorimetric methods provided similar P concentrations similar to those obtained by spectrophotometry (P>0.10). Using absorbance, the REP, LOD, and LOQ were 0.96%, 0.013, and 0.039 mg L−1, respectively. The best-performing image-based predictors were red and green channels of the smartphone, with REP, LOD, and LOQ values of 1.80%, 0.050, 0.150 mg L−1 and 2.11%, 0.074 and 0.223 mg L−1, respectively. The smartphone red channel spectrophotometric absorbance provided equivalent P concentrations at a 99% confidence interval. Smartphone images performed better than scanner images. The use of the mean red channel from smartphone images proved promising for determining P concentration in feeds.
dc.language.isoeng
dc.rightsopenAccess
dc.subjectAbsorbância
dc.titleColorimetric analysis of phosphorus concentration in animal feeds using images from smartphone or scanner: a proof-of-concept study.
dc.typeArtigo de periódico
dc.subject.thesagroMolibdênio
dc.subject.thesagroAlimentação
dc.subject.thesagroAnálise
dc.subject.nalthesaurusAbsorbance
riaa.ainfo.id1187968
riaa.ainfo.lastupdate2026-07-28
dc.identifier.doihttps://doi.org/10.37496/rbz5520250130
dc.contributor.institutionSUELLEN SOBRINHO FRANÇA MATTOS, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO; CRYSTHAL GONÇALVES DA SILVA, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO; LORHAINE BERNARDES DE LIMA, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO; LARYSSA RODRIGUES MAIA, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO; FELIPE DILELIS, UNIVERSIDADE DE SÃO PAULO; TADEU EDER DA SILVA, UNIVERSITY OF VERMONT; PLINIO DE FREITAS MARTINHO, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO; LUANA MARTA DE ALMEIDA RUFINO, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO; JOAO PAULO PACHECO RODRIGUES, CNPGL.
Appears in Collections:Artigo em periódico indexado (CNPGL)

Files in This Item:
File SizeFormat 
Colorimetric-analysis-of-phosphorus-concentration-in-animal.pdf1,04 MBAdobe PDFView/Open

FacebookTwitterDeliciousLinkedInGoogle BookmarksMySpace